Single-acting vs double-acting hydraulic cylinders
The difference is one port. A single-acting cylinder uses oil to push and lets the load bring it back. A double-acting cylinder uses oil both ways, so it pushes and pulls under power.
| Single acting | Double acting | |
|---|---|---|
| Ports | One | Two |
| Extends by | Oil pressure | Oil pressure |
| Retracts by | Load, gravity or a spring | Oil pressure |
| Hoses from tractor | One | Two |
| Typical uses | Dump boxes, lifts, hoists, plow lift | Loaders, implements, splitters, top links, angle rams |
| Pull force | None | Smaller than push, because the rod takes up area |
Choose single acting when weight always returns the rod, for example a dump box or a lift table. You save a hose and a valve section.
Choose double acting when you need to pull, hold a position in both directions, or work sideways or upside down. Almost every loader, implement and attachment cylinder is double acting.
Pull force on a double-acting cylinder is lower than push force, because the rod takes up part of the piston area. The force calculator shows both.
Can't find your size?
Send the bore, stroke, rod and pin-to-pin length, or a photo with a tape measure. We reply by email with a matching size or a custom quote.